Raychem HWAT-M Self Regulating Trace Heating Cable (9W/m at 55°C)

View all Cable

Raychem HWAT-M Self Regulating Trace Heating Cable (9W/m at 55°C)
Raychem HWAT-M Self Regulating Trace Heating Cable (9W/m at 55°C)
Raychem HWAT-M Self Regulating Trace Heating Cable (9W/m at 55°C)
Raychem HWAT-M Self Regulating Trace Heating Cable (9W/m at 55°C)
  • 10-year warranty
  • Tested and approved to IEC 62395 and IEEE 515.1
  • Proven useful lifetime in excess of 40 years
  • Water maintained at a specific temperature level

View full description

Quick Find: 459
Part Code: 498639-000

Weight: 0.14 Kg

This product is currently awaiting on stock arrival and due in soon.

This product is currently awaiting on stock arrival and due in soon.

Backorder now to secure your delivery or sign up to be notified when this product is back in stock.


Free Delivery Available*
£13.37 ex VAT
£16.04 inc VAT
£16.04 inc VAT
£13.37 ex VAT
Stock Available: 4727 Units

Per M Qty

Estimated delivery: 1 working days

Day of Choice Delivery Available

Made To Order This is a made to order product and therefore cannot be returned or cancelled

Hot water temperature maintenance self-regulating heating cable - 9 W/m at 55 Deg C

The nVent RAYCHEM HWAT self-regulating heating cables maintain the desired water temperature in a building’s hot water distribution pipe network.

Positioned on the pipe underneath the insulation, the cables automatically compensate for pipe heat losses where they occur, thereby providing continuous, energy efficient, hot water temperature maintenance.

The HWAT system can be used to eliminate the re-circulation system altogether or to help optimise it’s performance, in a hybrid approach.

In a hybrid system, recirculation loops are used on the long central pipe runs, with HWAT cables installed on all branch run outs.

Either way, a much improved solution when compared to re-circulation systems.

Technical specifications

BrandnVent
Maximum exposure temperature65°C
Minimum installation temperature100 m (20 A)
ModelHWAT-M
Nominal power output9 W/m at 55 °C

Product downloads

Raychem DS EU0537 HWATLMR EN